Gravel Driveway Calculator

Calculate a gravel driveway in the two layers it is built from: a compacted sub-base (commonly MOT Type 1 at 100-150mm) and a dressed gravel surface (20mm gravel at 40-50mm). Run the calculator once per layer and add the totals.

FreeInstant resultsUK planning data

Advanced calculator

Gravel Driveway Calculator

1

Project setup

Start with a preset or configure everything yourself.

2

Area and shape

Use the shape that most closely matches the area you are covering.

3

Depth and ordering allowance

Depth has a large effect on quantity. Use the finished compacted depth where relevant.

Advanced options
Bag formats

More than one area?

Plan the whole project

Combine areas and layers, then see an order total for each material.

Open project planner →

Converter

Tonnes ↔ cubic metres

1 m³ = — tonnes

Saved locally

Recent calculations

Your recent calculations stay in this browser.

Reference data

Material planning densities

Use supplier product data whenever available. These figures are planning defaults.

MaterialCategoryPlanning densityTypical rangeCompaction

Overview

A single deep gravel layer without a sub-base rutts and migrates — the layers, not total depth, make the drive.

How the calculation works

Sub-base tonnes = driveway area × compacted sub-base depth × 2.2 t/m³ (Type 1), plus compaction allowance when ordering loose.

Surface tonnes = same area × gravel dressing depth (40-50mm) × 1.6 t/m³.

A 50 m² drive at 125mm Type 1 plus 50mm gravel needs roughly 13.75 t of sub-base and 4 t of gravel before allowances.

Worked example

Driveway 10m × 5m (50 m²): 125mm MOT Type 1 sub-base plus 40mm of 20mm gravel.

Sub-base: 50 × 0.125 × 2.2 = 13.75 tonnes; with 10% allowance order 15.1 tonnes.

Gravel: 50 × 0.04 × 1.6 = 3.2 tonnes; with a 10% allowance, order about 3.5 tonnes.

MOT Type 1 at a glance

  • Planning density2.20 t/m³
  • Typical range2.00–2.30 t/m³
  • CategorySub Base
  • CompactionOften relevant
  • SourcePlanning midpoint of published UK supplier data (≈2.0–2.3 t/m³ range observed)
  • Reviewed2026-08-16

MOT Type 1 coverage guide

DepthArea per tonneArea per 850kg bagWeight per m²
25mm18.2 m²15.5 m²55 kg
40mm11.4 m²9.7 m²88 kg
50mm9.1 m²7.7 m²110 kg
75mm6.1 m²5.2 m²165 kg
100mm4.5 m²3.9 m²220 kg
150mm3.0 m²2.6 m²330 kg

Assumptions and accuracy

Sub-base depth is a design decision based on subgrade and use; 100-150mm is common for private cars, not a universal rule.

Check the specification required for your project and confirm quantities with your contractor or material supplier.

Edging, membrane and drainage are separate materials not included in the tonnage.

Planning density values

Use supplier product data whenever available. These figures are planning defaults shared by every calculator on the site.

MaterialCategoryPlanning densityTypical rangeCompaction
MOT Type 1Sub Base2.20 t/m³2.00–2.30 t/m³Relevant
MOT Type 3Sub Base2.10 t/m³1.90–2.20 t/m³Relevant
Recycled Type 1Recycled2.00 t/m³1.80–2.20 t/m³Relevant
6F2 / 6F5 crushed aggregateRecycled2.00 t/m³1.80–2.20 t/m³Relevant
Road planingsRecycled2.00 t/m³1.80–2.20 t/m³Relevant
Sharp sandSand1.60 t/m³1.50–1.70 t/m³Usually no
Building sandSand1.50 t/m³1.40–1.60 t/m³Usually no
Kiln-dried sandSand1.50 t/m³1.40–1.60 t/m³Usually no
10mm pea shingleGravel1.60 t/m³1.40–1.70 t/m³Usually no
20mm gravel / shingleGravel1.60 t/m³1.40–1.70 t/m³Usually no
Decorative gravelDecorative1.50 t/m³1.30–1.70 t/m³Usually no
Slate chippingsDecorative1.60 t/m³1.40–1.80 t/m³Usually no
Gabion stoneGravel1.50 t/m³1.40–1.60 t/m³Usually no
Self-binding gravelGravel1.90 t/m³1.80–2.10 t/m³Relevant
Crushed concreteRecycled1.90 t/m³1.70–2.10 t/m³Relevant
Limestone scalpingsSub Base2.00 t/m³1.80–2.20 t/m³Relevant
BallastSand1.70 t/m³1.60–1.80 t/m³Usually no
Generic aggregateGeneral1.70 t/m³1.50–2.20 t/m³Usually no

Typical depth guidance by project type

Project typeCommon depth rangeTypical materials
Driveway100–150mm compactedMOT Type 1, Recycled Type 1, 6F2 / 6F5 crushed aggregate
Garden path50–100mm compacted20mm gravel / shingle, Self-binding gravel, Decorative gravel
Patio sub-base75–100mm compactedMOT Type 1, Recycled Type 1, Sharp sand
Decorative border40–50mm compactedDecorative gravel, Slate chippings, 10mm pea shingle
Shed base75–100mm compactedMOT Type 1, Limestone scalpings, Ballast
Drainage layer50–150mm compacted10mm pea shingle, 20mm gravel / shingle
General fill100–300mm compacted6F2 / 6F5 crushed aggregate, Crushed concrete, Generic aggregate

How to use this calculator

  • Measure the full driveway area including any turning spaces.
  • First run: select MOT Type 1 and enter the sub-base depth; note the tonnage.
  • Second run: select 20mm gravel and enter 40-50mm; note the tonnage.
  • Add both totals with their allowances for the complete order.

When a gravel driveway is commonly used

Gravel driveways on firm subgrade with secure edging; the same two-layer method sizes parking bays, hardstandings and gravel paths for foot traffic (with shallower layers).

Frequently asked questions

How much gravel do I need for a driveway?

For the surface dressing allow 64-80kg per m² (40-50mm of gravel). The sub-base beneath is a bigger order: 220-275kg of Type 1 per m² at 100-150mm compacted.

What gravel is best for a driveway?

A 20mm angular gravel knits and resists scatter; avoid 10mm pea shingle on turning areas. Angular gravel over a Type 1 sub-base is the standard combination.

How deep should a gravel driveway sub-base be?

Private driveways commonly use 100-150mm of compacted Type 1, but soft ground or heavier vehicles can require more. This is an engineering decision for your specific site.

How do I stop gravel migrating off the driveway?

Run continuous edging or kerbs flush with the surface, keep the gravel dressing to 40–50mm, and use a 20mm angular gravel — it knits together, while rounded pea gravel rolls and spreads.